{"product_id":"gema-mdc-plus-400-basismodul-heizmodul-ohne-heizstab","title":"GEMA MDC PLUS 400 heating module without heating element","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Area of Application\u003c\/h2\u003e \u003cp\u003eThe GEMA MDC PLUS 400 base module is a heating module body for central heating systems and is supplied without a heating element. It serves as a hydraulic base for integrating a separately selected 400 V electric heating cartridge with 9.0 kW into the heating circuit.\u003c\/p\u003e \u003cp\u003eThe module is suitable for additional heating of heating water in systems with an existing main heat source, for example with solid fuel boilers, water-bearing fireplace stoves, gas or oil boilers, as well as heat pumps. Typical areas of application are supplementary heating, frost protection support, emergency heat, or the use of excess PV electricity via a suitable electric heating cartridge.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe GEMA MDC PLUS 400 base module consists of a steel tank with raw steel on the inside and a powder-coated surface on the outside. Thermal insulation is provided by 50 mm polyurethane foam; the outer cladding is made of plastic with a lid made of ABS plastic.\u003c\/p\u003e \u003cp\u003eFor hydraulic integration, the module has connection stubs with female thread G 1 1\/4\u0026quot;. The receptacle for the electric heating cartridge is designed as female thread G 1 1\/2\u0026quot;. For the MDC PLUS 400, a 400 V heating cartridge with 9.0 kW is intended; the heating cartridge must be selected separately and is not included in the scope of delivery for this item.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe base module enables a clear separation between the heating module and the heating cartridge. This allows the suitable 9.0 kW heating cartridge to be selected specifically according to the system concept, electrical design, and intended purpose.\u003c\/p\u003e \u003cp\u003eDuring operation, the module can provide support as an additional heat source when heating water in the heating circuit is to be electrically reheated. The specific function, temperature control, and electrical wiring depend on the heating cartridge used and the professionally installed system control.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe GEMA MDC PLUS 400 base module is intended for open or closed central heating systems with appropriate safety devices. The medium may be water or a glycol mixture suitable for heating systems up to a maximum concentration of 50%.\u003c\/p\u003e \u003cp\u003eIntegration is carried out in the parallel heating circuit on the flow or return of the main heat source. For proper operation, a functioning safety valve and an additional circulation pump must be planned to ensure the required minimum flow rate of the separately used heating cartridge.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical data at a glance\u003c\/h2\u003e \u003cp\u003eThe following information refers to the GEMA MDC PLUS 400 base module without the supplied heating element.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eSuitable heating cartridge\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e400 V, 9.0 kW, to be selected separately\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eConnection size\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/4\u0026quot;\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating cartridge connection\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/2\u0026quot;\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDevice length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e850 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e10 bar \/ 1.0 MPa\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMinimum flow rate at 9.0 kW\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e514 l\/h\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMaterial\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eSteel tank, raw steel inside, powder-coated outside\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eInsulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 mm polyurethane foam\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eInstallation, hydraulic integration, and electrical connection of the separately installed heating cartridge must be carried out by qualified specialists. The module is integrated into the parallel heating circuit of the main heat source; when routing the pipes, ensure complete filling and reliable venting.\u003c\/p\u003e \u003cp\u003eThe MDC PLUS 400 can be operated horizontally or vertically in accordance with the German manufacturer\u0026#39;s documentation. The final installation position must be checked against the currently supplied original documentation before installation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eThis article describes exclusively the GEMA MDC PLUS 400 base module without heating element. For this version, a suitable 400 V heating cartridge with 9.0 kW is intended. Smaller 400 V heating cartridges with 3.0 kW, 4.5 kW, or 6.0 kW belong to the MDC 400 logic and should not be assigned to this base module.\u003c\/p\u003e \u003cp\u003eOperation without water is not permitted. The electrical supply to the installed heating cartridge may only be activated after the system has been filled and vented. The safety valve, circulation pump, fuse protection, cable cross-section, and control connection must be designed on-site to suit the system and the selected heating cartridge.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eGEMA MDC PLUS 400 base module \/ heating module basic body without heating element\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Gema GmbH","offers":[{"title":"Προεπιλεγμένος Τίτλος","offer_id":47098442875228,"sku":"MDC400P","price":165.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/ModulMDC.png?v=1783743561","url":"https:\/\/cy.gemashop.de\/en\/products\/gema-mdc-plus-400-basismodul-heizmodul-ohne-heizstab","provider":"GEMA Shop","version":"1.0","type":"link"}