{"product_id":"pufferspeicher-sunex-fish-s4-200-x-209-liter","title":"Sunex FISH S4 200 X buffer tank 209 liters","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe Sunex FISH S4 200 X is a standing buffer tank with a storage capacity of 209 liters for heating systems with solid fuel boilers, oil or gas heating, heat pumps, or electric boilers. It serves to buffer system water and supports a more even hydraulic integration between the heat generator and the heating circuit.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe tank is designed as a buffer tank without an integrated heat exchanger. The vessel is made of S235JR, is automatically welded, and has a gray outer jacket. The hydraulic connections are designed as G 1 1\/2\u0026quot; female threads, and the sensor connections as G 1\/2\u0026quot; female threads.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eWith a capacity of 209 liters, the tank is particularly suitable for more compact heating systems where a manageable buffer volume is required. The connection arrangement allows flexible integration of the heat source, heating circuit, and temperature sensing. The 50 mm thick polyurethane foam insulation with PVC foil layer reduces heat losses and protects the tank in regular system operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe Sunex FISH S4 200 X can be used in systems with solid fuel boilers, oil and gas heating, heat pumps, or electric boilers. Solar support is not provided via an integrated heat exchanger in this tank series, but must be planned via suitable system hydraulics or an additional heat exchanger in the system. For use with chilled water from 7 to 12 °C, the connection stubs must additionally be insulated against condensation and heat absorption.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"product-th\"\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eSUNEX S.A.\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eFISH S4 200 X\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStorage type\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eBuffer tank without integrated heat exchanger\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStorage volume\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e209 l\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStandby heat loss\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e45 W\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e95 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e3 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eTest pressure\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e4.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eInsulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e50 mm polyurethane foam with PVC foil layer\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStorage tank material\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eS235JR\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDiameter with insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e607 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDiameter without insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e500 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeight \/ Diagonal\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1306 \/ 1395 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHydraulic connections\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eG 1 1\/2\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSensor connections\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eG 1\/2\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eVenting\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eG 1 1\/2\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e49 kg\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe storage tank must be installed vertically on a level, load-bearing surface. Before installation, check the transport route, room height, door widths, floor load, and connection side. All connections must be made without tension, unused connections must be properly sealed, and venting must be provided at the highest point of the system.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eThe storage tank is intended for heating or system water and is not described as a drinking water storage tank. Installation, connection, commissioning, and maintenance must be carried out by qualified personnel in accordance with applicable engineering standards. Operating pressure, temperature limits, and proper hydraulic planning must be observed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eSunex FISH S4 200 X buffer storage tank 209 liters\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Sunex","offers":[{"title":"Προεπιλεγμένος Τίτλος","offer_id":55287768088924,"sku":"SS4200","price":466.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/Sunex_Fish_S4.png?v=1782722048","url":"https:\/\/cy.gemashop.de\/en\/products\/pufferspeicher-sunex-fish-s4-200-x-209-liter","provider":"GEMA Shop","version":"1.0","type":"link"}